| Tonometer, H-S BP/BQ/BX Slit Lamp |
More Info
|
|
|
|
| Stock : No |
This model of the Goldmann applanation tonometer is designed for the Haag-Streit BP 900, BQ 900 and BP 900 slit lamps. It mounts onto the microscope and can be swiveled into position when required.
The Applanation Tonometer AT 900 BQ is especially made to fit the BQ stereo-microscope. Apart from the working position, there are also two resting positions.
For perfect tonometric examination the tonometer is swung in front of the microscope and the illumination unit moved from the left to touch the bracket of the tonometer. In this position, the left and right eye of the patient can be examined without difficulties (no 60° position).
Main features:
The measurement of the ocular pressure is carried out on the patient sitting at the slit lamp in conjunction with other routine microscopic examinations.
High accuracy of the measurement - the average deviation in any one single examination does not exceed ± 0.5 mm Hg.
The intraocular pressure in mm Hg is found by multiplying the drum reading by ten.
Scleral-rigidity is not to be taken into account as the small volumetric displacement of 0.56 mm3 increases the intraocular tension by about 2.5 % only.
Repeated measuring procedures do not reduce the ocular pressure, as no massaging effect occurs.
The instrument stays permanently mounted to the slit lamp and is swung into place when IOP readings are required.
Click here --> for brochure
Click here --> Tonometer disinfection instructions
Click here -->Haag-Streit recommended tonometer prism disinfection procedure instructions
|
 |
| Tonometer, Haag-Streit 870 Applanation |
More Info
|
|
|
|
| Stock : No |
The Applanation Tonometer 870 is to be mounted over the microscope of the slit lamp. The feeler arm protrudes from above into the path of the microscope and the illumination unit. The tonometer is ready for use with a single swing movement of the feeler arm
Designed to fit on most "Zeiss" style model slit lamps. This high quality instrument provides highly accurate intra-ocular pressure readings.
The instrument stays permanently mounted to the slit lamp and the prism is swung down when IOP readings are required.
The Applanation Tonometer is still the most widely used instruments to measure interocular pressure. The advan-tage of the "Goldmann" method are considerable. The measurement can be carried out on the patient sitting at the slit lamp in conjunction with other routine microscopic examinations. The accuracy of the measurement is ex-tremely high. The average deviation in any one single examination does not exceed +/- 0.5. mm HG. Furthermore, repeated measuring procedures do not reduce the ocular pressure, as no massing effects occurs. Last but not least, there are no standardization or calibration difficulties.
Main features:
The measurement of the ocular pressure is carried out on the patient sitting at the slit lamp in conjunction with other routine microscopic examinations.
High accuracy of the measurement - the average deviation in any one single examination does not exceed ± 0.5 mm Hg.
The intraocular pressure in mm Hg is found by multiplying the drum reading by ten.
Scleral-rigidity is not to be taken into account as the small volumetric displacement of 0.56 mm3 increases the intraocular tension by about 2.5 % only.
Repeated measuring procedures do not reduce the ocular pressure, as no massaging effect occurs.
There are no standardisation and calibration difficulties.
Click here --> for brochure
Click here -->Haag-Streit recommended tonometer prism disinfection procedure instructions
|
 |
| Tonometer, Haag-Streit R-900 Applanation |
More Info
|
|
|
|
| Stock : No |
The Applanation Tonometer 900, an accessory to the Slit Lamp 900, can be especially adapted in an optimum manner to combine with other HAAG-STREIT equipment. Because of its versatility, the Applanation Tonometer can also be mounted onto and combined with other equipment.
Designed to fit the Haag-Streit 900BM slit lamp. This model also fits on most Haag-Streit style slit lamps. This high quality instrument provides highly accurate intra-ocular pressure readings.
Main features:
The measurement of the ocular pressure is carried out on the patient sitting at the slit lamp in conjunction with other routine microscopic examinations.
High accuracy of the measurement - the average deviation in any one single examination does not exceed ± 0.5 mm Hg.
The intraocular pressure in mm Hg is found by multiplying the drum reading by ten.
Scleral-rigidity is not to be taken into account as the small volumetric displacement of 0.56 mm3 increases the intraocular tension by about 2.5 % only.
Repeated measuring procedures do not reduce the ocular pressure, as no massaging effect occurs.
The instrument stays permanently mounted to the slit lamp and is swung into place when IOP readings are required.
Click here --> for brochure
Click here -->Haag-Streit recommended tonometer prism disinfection procedure instructions
|
 |
| Video Digital Package IM 900 for BQ |
More Info
|
|
|
|
| Stock : No |
|
The Haag-Streit Digital Video Imaging Module IM 900 is an integrated imaging solution for the BQ 900. The IM 900 consists of a compact camera module including beam splitter with capture module and cabling. The IM 900 will adapt to any existing HS 900 BQ slit lamp. IM 900 System includes: IM 900 Imaging Module EyeCap Software 19” LCD Monitor & CPU Capture Module HS Cold Light Source Mirror w/Mirror Support Fiber Optic Cable Suggested Retail = $13,495
|
 |
| Video Relay Lens, For H-S 900BQ |
More Info
|
|
|
|
| Stock : No |
|
This Haag-Streit model of the video relay lens is designed forstandard size C mount CCD video cameras. It attaches to the beam splitter and is designed for the 900BQ slit lamp.
|
 |